Fault Simulation on Electrical Machines Training System
Simply plug the fault simulator into a three-phase asynchronous motor. The widest range of realistic faults can be activated using lockable fault switches. These faults can be detected and analysed using industrial-type measuring instruments. Repair measures can be worked out on the basis of the measuring results. All measurements are performed with the power switched off.

Power Classes Available: 0.3 & 1 kW
Training Concepts:
  • Winding breaks in coils
  • Winding-to-winding insulation faults
  • Winding-to-housing insulation faults
  • Combination of various faults
  • Fault assessment and practical repair measures
  • How to handle insulation meters
Product: Fault Simulation on Electrical Machines Training System
Product Code: EEM 4.5

Information cart is empty!